ks凯时




    About
    Testing Capability
    Committed to becoming your trusted filter manufacturer
    Index/R&D/Testing Capability

    Testing Capability

    Filter

    Filter material filtration efficiency and resistance
    measuring table

    Reference testing standard: IEST-RP-CCO21.3
    Test object: filter material
    Test item: Filter material filtration efficiency, resistance
    Test accuracy range: Filtration efficiency range: 20% -99.9995% Test air volume: 30L/min360L/min
    Particle counter model: PMS Lasair ? Ⅲ110

    Filter leakage detection system

    Reference testing standard: EN18822-4
    Test object: filter, filter material
    Test item: Check if the filter leaks

    Filter efficiency and resistance
    test bench (low air volume)

    Reference testing standard: IEST-RP-CCOO7.2, ANSI/ASHRAE 52.2
    Test objects: air purifier filter, vacuum cleaner filter
    Test items: Filter filtration efficiency, initial resistance
    Testing accuracy range: Filtering efficiency range: 20% -99.99% (0.1-1.0 μ m)
    Test air volume: 5m3/h~42m3/h
    Particle counter model: TOPAS LAP 340/TSI 3330

    Filter efficiency and resistance
    test bench (stroke volume)

    Reference testing standard: IEST-RP-CCOO7.2
    Test objects: air purifier filter, vacuum cleaner filter
    Test items: Filter filtration efficiency, initial resistance
    Testing accuracy range: Filtering efficiency range: 20% -99.9995% (0.1-1.0 μ m)
    Test air volume: 10m3/h~200 m3/h
    Particle counter model: PMS Lasair ? Ⅲ110

    Filter efficiency and resistance measurement air duct

    Reference testing standard: GB18801-2022 IEST-RP-CCOO7.2、ASHRAE52.2
    Test objects: air purifier and its filter, fresh air fan filter
    Test items: Initial filtration efficiency, initial resistance, and related PQ curve diagram Test principle: Test and evaluate the initial efficiency, resistance, and other performance of an air purifier or air filter at rated air volume Test accuracy range: Filtration efficiency range: 20% -99.9995% (0.1-1.0 μ m) Test air volume: 100m3/h~2000 m3/h
    Particle counter model: PMS Lasair ? Ⅲ110

    Detecting system

    Purifier

    Particle CADR measurement experimental chamber

    Reference standards: GB/T 18801-2022 ANSI/AHAM AC-1-2020
    Test object: Air purifier and fresh air fan
    Test item: (PM2.5, PM1.0) particulate matter clean air volume
    Test chamber volume: 30m ?
    Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic cigarette smoke generator

    Gaseous pollutant CADR measurement experimental chamber

    Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
    Test object: Air purifier and fresh air fan
    Test item: Formaldehyde clean air volume
    Test chamber volume: 30m ?
    Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010 Pro

    81 cubic CADR measurement experimental chamber

    Reference standard: GB/T 18801-2022, GB/T 18204.2-2014
    Test object: Air purifier and fresh air fan
    Test items: particulate matter, formaldehyde, VOC clean air volume
    Test chamber volume: 81m ?
    Equipment configuration: Laser aerosol particle size spectrometer (TSI3340), fully automatic cigarette smoke generator

    VOC CADR
    Measurement laboratory

    Reference standard: GB/T 18801-2022, GB/T 18883-2022
    Test object: Air purifier and fresh air fan
    Test item: Gaseous pollutants (toluene, TVOC) Clean air volume
    Test chamber volume: 30m ?
    Equipment configuration: Air sampler, thermal desorption instrument, gas chromatograph TD-30/GC-2010 Pro

    CCM experiment chamber for particulate matter
    CCM experimental chamber for gaseous pollutants

    Reference testing standard: GB/T 18801-2022
    Test objects: air purifier, fresh air fan
    Test items: Cumulative purification of particulate matter, cumulative purification of gaseous pollutants (formaldehyde, toluene, TVOC)
    Test chamber volume: 3m ?
    Equipment configuration: fully automatic cigarette smoke generator, fuel injection pump

    Ozone testing
    Experimental cabin

    Reference testing standard: UL867
    Test objects: air purifier, fresh air fan
    Test items: 24-hour ozone production, one-time ozone filtration efficiency, ozone lifespan
    Test chamber volume: 30m ?
    Equipment configuration: Ozone detector (MODEL-T400)

    Detection system

    Vacuum cleaner/sweeping machine

    Dust bag detection system -
    Dust capacity/resistance

    Reference standards: ANSI/ASHRAE 52.2 ISO/TS 11155-1
    Test object: Vacuum cleaner filter, dust bag
    Test items: dust holding capacity, resistance
    Testing principle: By loading dust into the filter or dust collection bag, the final resistance is tested according to the set loading amount and time to determine the dust holding capacity of the filter or dust collection bag

    Dust bag detection system -
    filtration efficiency/resistance

    Reference standard: EN779, ANSI/ASHRAE 52.2、ISO/TS 11155-1
    Test object: Vacuum cleaner filter, dust bag
    Test items: dust holding capacity, resistance
    Testing principle: By loading dust into the filter or dust collection bag, the final resistance is tested according to the set loading amount and time to determine the dust holding capacity of the filter or dust collection bag

    Detection system

    Water purification filter element

    Labeling - Life Test Bench - (Residual Chlorine/Hardness)

    Reference standard: HJ 586-2010 Determination of free chlorine and total chlorine in water quality
    Test object: Water purification filter
    Test item: residual chlorine, total hardness
    Testing principle: Residual chlorine: Free chlorine reacts directly with N, N-diethyl-1,4-phenylenediamine (DPD) to produce a red compound, and its absorbance is measured by spectrophotometry. Total hardness: Calcium and magnesium ions in the water sample form a purple red chelate with the chromium black T indicator. When pH=10, disodium ethylenediaminetetraacetic acid first forms a chelate with calcium ions, and then with magnesium ions. When titrated to the endpoint, the solution appears pure blue with the chromium black T indicator.

    Water Hammer Laboratory Platform

    Reference standard: GB/T 30307-2013 Household and Similar Use Drinking Water Treatment Equipment Test object: Household and similar drinking water treatment devices
    Test items: hydrostatic pressure, rupture test, cyclic pressure
    Testing principle: Conduct several impact experiments on the tested object by simulating the water pressure in use to verify whether its structural strength can meet the usage requirements

    Conductivity/pH testing bench

    Reference standard: GB/T 5750.4-2023 Standard Test Method for Drinking Water
    Test object: Drinking water
    Test items: Conductivity, pH
    Testing principle: When the concentration of hydrogen ions changes, the electromotive force between the glass electrode and the calomel electrode also changes. At 25 ℃, each unit of pH scale is equivalent to a change in electromotive force of 59.1 mV, which is directly represented by the pH reading on the instrument.

    Activated carbon performance testing (iodine value/ash content/hardness)

    Reference standards: 1. GB/T 12496.8-2015 Test methods for wooden activated carbon Determination of iodine adsorption value
    2. GB/T 12496.5-1999 Test methods for wooden activated carbon Determination of carbon tetrachloride adsorption rate (activity) 3. GB/T 7702.3-2008 Test Method for Granular Activated Carbon from Coal - Determination of Strength Test object: Activated carbon
    Test items: Iodine adsorption value, carbon tetrachloride adsorption capacity, strength

    Detection system

    Chemical analysis

    Multifunctional Chemistry
    Analysis and Testing Laboratory

    Testing of water filtration projects for the development of catalysts and chemical formulas corresponding to formaldehyde, ozone, and other VOCs: According to CNAS accreditation, water conductivity, pH value, hardness and other items can be tested and evaluated

    Meteorological chromatography
    Analyzer

    Reference standards: GB/T 18801, GBT18883
    Test object: Gaseous (volatile and semi volatile compounds)
    Test items: TVOC, toluene, benzene

    Spectrophotometer

    Reference standards: GB/T 18801, GBT18883
    Test object: Formaldehyde
    Testing principle: Quantitative analysis of sample substances using the visible spectral region

    Detection system

    Product reliability

    High temperature and high humidity experimental chamber
    Cold and hot shock experimental chamber

    Reference standard: ISTA
    Can the product structure of the simulated filter meet the requirements under extreme environmental conditions of long-term storage and maritime transportation

    Flame retardant testing chamber - European standard
    Flame retardant testing chamber - American standard

    Reference standards: UL94/UL900, EN, GB/T5169
    Conduct combustion testing on the filter element and raw materials according to relevant standards to evaluate whether they meet the corresponding flame retardant level requirements

    Salt spray test
    Experimental cabin

    Reference standards: GB2423.17, IEC60068-2-11
    Conduct salt spray testing on the filter element and raw materials according to relevant standards to evaluate whether they meet the corresponding corrosion resistance requirements

    Detection system

    Packaging Material Verification Laboratory

    Crane arm drop tester

    Reference standard: ISO2248 JISZ0202-87 GB/T4857.5
    Test method: Full range drop of surface, angle, and edge
    Drop height mm: adjustable from 300-1500
    The maximum weight of the specimen is kg: 0-80kg < br /> Falling height error: 1%

    Paper box compression tester

    Reference standard: GB/T 4857.4 GB/T 4857.3
    Measurement range ≤ 10KN
    Distance between upper and lower pressure plates: 800mm
    Measurement range: 800 * 800 * 800MM
    Measurement accuracy: ≤± 1%
    Compression speed: 0-85 mm/min (adjustable speed)

    Electromagnetic vibration test bench

    Reference standard: ISO 2247 ISO 13355 IEC 60068 ASTM D999 ASTM D4728 ASTM D3580 GB/T 4857 GB/T 2423
    Frequency accuracy: 0.1Hz
    Amplitude (mm) : 0-5
    Vibration direction/waveform: triaxial (X+Y+Z)/sine wave
    Test mode: fixed frequency, sweep frequency, double frequency, program, logarithm, random
    Table size (mm) : (W) 800 x (D) 800 x (H) 720